Standby power systems WA NOTSTROMTECHNIK WA Y 45 S RC 2

energy & engines: power generators, engines, turbines, boilers / power generators / Standby power systems

item-No.: 162153825 Quantity: 1 Date: 16.09.2024
Year of manufacture: new machine Location: 33415 Verl
Price: request quote
Manufacturer: WA Notstromtechnik
Model: WA Y 45 S RC 2
Type of machine: Standby power systems
Description: Standby power systems WA Notstromtechnik WA Y 45 S RC 2

new machine

Sabotage-proof RC 2 emergency generator 41 kVA with internal automatic emergency power 72 hours with Yanmar engine 4 TNV 98 for mains parallel operation

Aggregate type: stationary

Design: Super soundproofed

Technical data engine:

Engine Manufacturer: Yanmar

Engine Model: 4 TNV 98

Engine No.: in production

Motor power: 37.7 KW electronically controlled

Cooling: Water-cooled

Tempering: Electric 12 V DC

Speed: 1500 rpm

Fuel: Fuel oil EN 590 and diesel B7

Technical data generator:

Generator manufacturer: Mecc Alte

Generator type: Sychron with AVR

Gene. No.: in production

Generator power: 45 kVA

Voltage: 400 / 231 volts

Power factor: cos. - PHI 0.8

Speed: 1500 rpm

Switchgear:

Version: Automatic start

Functions: Emergency power operation with ÃœSY

Tank:

Design: Base frame tank with drip pan

Capacity / litre: 990

Scope of delivery:

Design: Weatherproof, RAL 7046 (telegrau 2) soundproofed version essentially consisting of:

Our LZPD series was developed by us for the North Rhine-Westphalia State Police. Essentially, digital radio sites are supplied with backup power from the grid. Since some sites are very remote, special attention was paid to the monitoring of the plant and sabotage security. All doors have a 2-fold drive rod lock and can be adapted to the customer's own locking system with profile half cylinders 30/10 (not included).

The thermostatically heated system is equipped with a drip pan with optional leakage monitoring. The tank system is A1068 sufficient for at least 204 hours with 50% load. In full load operation, 109 hours are possible. The requirement of 72 hours is thus clearly exceeded.

The emergency power system is designed for fully automatic emergency power operation. In automatic mode, the unit is started immediately in the event of a power failure. When the nominal frequency and nominal voltage are reached, the mains contactor is switched off and the generator contactor is switched on within approx. 15 seconds. After the network is restored, the automatic uninterruptible switch back to mains operation takes place after the network has been checked (approx. 180 seconds).


seller offer No. resale 1381
Machine in stock: Yes