Model
(Manufacturer: SCHOLZ)
TÜV: all test documents available (partly in Czech) Feeding: Hot air (via steam-heated heat exchanger) Operating temperature: 130°C Ab. Operating pressure: 0.5 bar Test pressure: 3.3 bar Calculation overpressure: 2.5 bar Chamber volume: 21,900 l Loading Ø: 2000 mm Loading length: 6000 mm Loading: Carriage on roller conveyor, track gauge 870 mm Electrical control: PLC SIEMENS S5 with OP3 control panel, contactor control for Burner External insulation: 100 mm thick with 1 mm galvanized steel sheet Chamber door: open/close manually, locking via manual Bayonet quick-release fastener (limit switch monitored) Steam generators: Manufacturer: TRACTANT FABRI Kolín/ Czech Republic Type: TF 1700 Year of construction: 1996 Heating capacity: 1700 kW Fuel: Natural gas Steam temperature: 192°C Steam volume: 2.5 t/hour Burner: Manufacturer: Max Weishaupt GmbH/ Germany Type: ...
Scholz Steam Autoclave Year 1979 7 bar pressure Internal dims: 1.5m diam. x 2.6mm long Temperature 150deg C 10 x steam connectors Indirect steam Full rail system Machine overhauled 2016/17 Full safety certification available Complete with control panel
Scholz Autoclave 1.5m diam. x 3m long Electric heating Welded construction Quick lock door Year 1990 Working pressure 7 bar Working temp; 150deg C
Autoclave/Hardening boiler Manufacturer: Scholz & Co. Year of construction: 1996 Working pressure: 16 bar Working temperature: 203° C Volume: 101.800 liters Diameter: 2,000 m Length: 26 m Charging medium: saturated steam Quantity: 9 pieces (all identical) The autoclaves could be inspected at every time! In very good condition!