Manufacturer:
(Category: 1800)
Hitachi LaChrom Elite Ultra HPLC -L 2160U Gradient Pump with Degasser max. pressure 600 bar, max flow 5 ml/min -L-2200 U Autosampler/cooling -L2455U DAD/Diode Array Detector -L2350 Colcom/Column Furnace for 4 HPLC Columns Second L 2160U pump on request Price: VB ... more information
GE Äkta Explorer FPLC 100 Air/General Electric/Cytiva -Box 900 -pH/C 900 monitor -UV 900 UV Detector -UV Flow Cell -P 900 Pump /100ml/min w. Switch Valves Air 900 Control Box -pH Sample -Conductivity Cell -INV 907 Injection V1 Sample Valve V5 Outlet Valve V4 Column Valve V2 Column Valve V 3 -P 960 -M 925 MIxer (2ml) on request 5 and 12 ml) FR 902 Restrictor CU-950 Interface Unicorn Software -Frac 950 Faction Collector warranty
Dionex Aquion Ion Chromatograph with Autosampler AS-DV Double Piston Pump, Thermostatic Conductivity Cell Electrolytic Suppression, Column Heating, IOnPac CS 16 Column, Supressor CE S 500, Software Chromeleon 7.xx ... more information
Metrohm 907 Titrando with 804 Ti Stand dynamic (DET); monotonous (MET), endpoint (SET) enzymatic and ph-Sat, as well as Karl Fischer (KF) Titrations,Measurement with ion-selective electrodes "iTrode",Dosing function with monitoring, Complies with FDA/21 CFR 4 MSD ports, USB Dosino 800; 10 ml ; 804 Ti Stand
Agilent 5973 N MSD Detector with Edwards turbomolecular pump or diffusion pump, used and refurbished on request also complete as measuring station with Agilent 6890GC Please inquire about the price per piece ... more information
Ehret Sterilizer ST 637, used, Volume 640 Liter,completely made of stainless steel, Special Design, SPS Control, Process documentation, Temperature +5 to 250 � C Dimensions: W x H x D: 98 x 100 x 68 cm ... more information
Agilent G 1321A Fluorescence Detector Ex Monochromator range 200 – 700 nm Em Monochromator range 280-900 nm Wavelength characteric Repeatability +/- 0.2 nm Accurcacy +/- 3 nm Flow cell 8μl Analog Output/Recorder/Integrator 100mV or 1 V Communications: CAN, GP-IB, RS 232; LAN Remote: ready, start, stop and shut down signals
Agilent G 1362 A RID Detector Refractive Index Range 1.00-1.75 RIU Measurement Range +/- 600x 10-6 RIU Sample Cell 8 ul Analog Output/Recorder/Integrator 100mV or 1 V Communications: CAN, GP-IB, RS 232; LAN ... more information
Hitachi HPLC System LaChrom Elite -Power Box -L 2130 Gradient Pump -L 2300 Column Thermostat -L 2200 Autosampler (cooling) -L2455 DAD Diode Array Detector ... more information
Perkin Elmer Lambda 365 UV-VIS Spectrophotometer, Dual-beam device Wavelength range 190-100 nm variable bandwidth 0.5-20 nm 10 mm cuvette holder ... more information
Eppendorf Mastercycler ep Gradient S PCR/Thermalcycler 96 well-plates or tubes heatable lid Graphically programmable Ramp rate 6C/sec, cooling 4.5 C/sec Temperature range 30C to 99C, lid 37-110C Temperature constant +/- 0.2 C ... more information
Millipore IsoPak STS, System equipped to pack and unpack columns for Millipore K Prime Biochromatography system year of manufacturing 2000 ... more information
Millipore K-Prime III Biochromatography system for cleaning and separation of proteines, biotechnology products, antibodies etc. The System is GMP-conform. floating rate 1-10 l/min, nominal pressure 7 bar, UV-H and LF Messuring after column, fraction sampler valves The System is consisting of corrosion-resistant materialials like lastic and Hastelloy-C.
GE Äkta Purifier 10 FPLC System Box 900 P 900 Pump /10 ml pump heads UPC 900 Monitor INV 907 Valve M925 Mixer / 6 ml mixing chamber Conductivity Flow Cell pH Sample CU 950 Interface/Communication Module FRAC 920 Fraction Collector Unicorn Software ... more information
Beckman HPLC Plant System Gold, Gradient Pump Model 128 0,01 to 10 ml/min and DAD Detector complete with Software 32 carat ... more information
Perkin Elmer PinAAcle 900 F Flame AAS Perkin Elmer AAS PinAACle 900F F Flame AAS True double beam, 8 –lamp mount, Fibre Optic light path automated flame and burner optimization PC and Perkin Elmer WinLab Software Lamps on request Last Service 07/2022 with warranty ... more information
Agilent 5973 MSD Detector,Network/LAN Connector, Diffusion pump, completely overhauled ... more information
Dionex ICS 90 Ion Chromatograph, Ion chromatograph with conductivity measuring cell, Suppressor technology, Pump: Flow rate 0.5 – 4.5 mL/min Detector range: 0-500 μS or 0-10 000 μS (selectable) DS 55 Detection stabilizer, Ion Pac AG 23/4 x 50 mm Gurad, Dionex 4 x 250 mm Analytical Connectors: USB and TTL
Agilent 5973N inert MSD with GC Agilent 6890 N Agilent 5973 N inert MSD with GC Agilent 6890 N Network Agilent 5973 inert MSD with EI and turbomolecular pump enhanced BOC Edwards Turbopump Agilent GC 6890 Network with Split/Splitless Injector/EPC Edwards Vacuum Pump 1.5 MSD Productivity Chemstation E02.02 on PC/Win 10 NIST on request Option: Agilent Liquid Sampler, CTC or Gerstel MPS2 Sampler currently serviced/with warranty Installation on request
Perkin Elmer Lambda 25 UV VIS Spectrophotometer, Dual-beam device, wavelength range 190-1100nm, 10 mm or 100mm cuvette holder, Option flow-through cuvette with peristaltic pump, Software Perkin Elmer WinLab ... more information