Fabricante:
(Categoría: 705)
I am selling a sandblaster with dimensions of 50x43cm. For more info and photos, contact by email or phone. Price negotiable ... más información
Two-stage oil vacuum pump with the following parameters: Capacity: 8 m3/h Final vacuum: 2 x 10-3 mbar Power consumption: 370 W Oil quantity: 1 liter Speed: 1450 rpm Noise level: 50 dB(A) Inlet/outlet connections DN 16 KF Dimensions: 463 x 157 x 230 mm (L x W x H) Weight: 22.5 kg Distinguishing features: - low noise level - high degree of reliability with stable operation - pump chamber and interior covered with protective PTFE coating - larger oil chamber reducing the risk of oil decomposition by aggressive solvent vapors due to high dilution effect - larger cooling surface to slow down the corrosion process - compact pump design, easy to carry thanks to the ergonomic handle - low heating of the pump during operation - extended oil change and service intervals - ballast gas valve - non-return valve - easy service - low maintenance costs - CE certificate
The reactor volume of 150 l (Useful volume of 120 l) is designed for the preparation, sterilization and storage of technological solutions and nutrient medium, as well as for separate collection of biomass concentrate and supernatant after centrifugation. The reactor is made in pharmaceutical design, and the total volume of the reactor vessel in the geometric ratio H / D = 2 (height to diameter); made of AISI 316 L stainless steel, equipped with a Rushton type bunker turbine mixer, has a removable elliptical cover, elliptical bottom and top magnetic drive. The reactor vessel provides for the installation of sensors and regulatory elements of the process control interface.
Medical sterilizer For decontamination of various materials, including liquids in sealed bottles. It is built between two rooms in one wall. Cabinet and through execution. The internal dimensions of the camera are 672 x 672 x 600 (W x H x D). The volume of the camera is 300 liters. The software combination L 3203 is designed to sterilize dishes, textiles, rubber plugs, filters and liquids in closed or ventilated rigid containers. All processes in this combination are designed to retain and disinfect wastewater from the sterilizer. The parameters for each process can be adjusted and stored in memory for the respective program. Vertically sliding doors with a lock when an obstacle occurs. Microcomputer-based PACS 3500 control unit. Russified display. Avanti control panel (8.4 color, touch / touch screen) on the loading and unloading side. A tight seal to prevent contamination - ...
Medical sterilizer for decontamination of various materials including liquids in open containers. Built between two rooms in two walls. Left service. The internal dimensions of the camera are 672 x 672 x 1000 (W x H x D). The volume of the camera is 452l. The P 3203 software combination is designed to sterilize dishes, textiles, rubber plugs, filters and liquids. All processes in this combination are designed to retain and disinfect wastewater from the sterilizer. The parameters for each process can be adjusted and stored in memory for the respective program. Vertically sliding doors with a lock when an obstacle occurs. Microcomputer-based PACS 3500 control unit. Russified display. Avanti control panel (8.4 color, touch / touch screen) on the loading and unloading side. A tight seal to prevent contamination - on the loading side (SPF flange). Set of pipelines for connecting ...
Mechanical convection cooling incubator (2pcs) For complex experiments on the incubation of microorganisms with their minimal dehydration without condensation in the inner chamber of the incubator. Has a programmable controller with a weekly programming timer. Temperature range from -5 to 100C, external dimensions 925 1945V 800, 1 external door and 1 internal glass door. The volume of the chamber is 400 l. Extendable grill 2 pcs. Weight (empty) 220 kg. Temperature variation max. +/- 0.6K, degree of protection IP according to EN 60529 IP 20. rated voltage at 240 V 1.4 kW.
The MF-L40 type filter mixer is designed for collagen processing in the cosmetic industry. It is used to rinse products with CIP heads while simultaneously mixing and discharging the rinsate. The device is designed to work in a non-pressurized condition or with a generated vacuum. I have 3 such devices for sale The offer is for 1 piece
Centrifuge OTR - 102 K - 01 is a clarifying, vertical, tubular machine with manual sediment unloading. The centrifuge is designed to clarify suspensions by sedimenting particles under the influence of centrifugal forces. The centrifuge can process suspensions with a finely dispersed solid phase, with a solid particle content of up to 1% and a ratio of specific gravities of the solid and liquid phases of at least 1.1. Technical data: Centrifuge weight 355 kg. , Overall dimensions: LxWxH (mm) - 970x470x1830, rotor working volume, l - 6, maximum/working separation factor - 16940/13200, drive electric motor: power - 3 kW, voltage, V - 380. Complete with centrifuge: technical description and operating instructions, a form, a set of spare parts, a lubricant supply system for the centrifuge rotor supports, a tool kit with a box.
Industrial Bioreactor 300 liters - Howard GBR We are selling a high quality industrial bioreactor, Howard brand, ideal for biotechnological and fermentation processes. ... más información
It is an FDA approved device that can work simultaneously with ultrasound and radiofrequency energy. The device, which is referred to as satin body lift, can be applied to every part of the body. ... más información
Equipment: Continuous mixing plant type: Schugimix sxb-335 manufacturer: HOSOKAWA ALPINE AG (GERMANY) industries APPLICATIONS: chemical, mining year of manufacture: 2020 CONDITION: NEW (NOT USED) PC. in stock:1 ... más información
Used Brogli & Co model Multi Homo MH 500 stainless steel vacuum homogenizer. Jacketed mixing vessel has 568 litre total capacity, approximately 500 litre working capacity. Central discharge with manual valve. Internal rated +0,5/-1 bar maximum pressure at 120°C maximum temperature. Stainless steel jacket has volume 65 litre, rated 1 bar maximum pressure at 120°C maximum temperature. Has Multi Homo mixing system - (1) homogenizer 1500/3000 rpm, (1) anchor agitator with scrapers 14/28 rpm and (1) ribbon agitator 22.1/44.2 rpm. Anchor agitator and ribbon agitator are driven by 6.4/8.2 kW, 1450/2900 rpm, 380 V, 50 Hz electric motor. Homogenizer is driven by 8.5/11 kW, 1470/2920 rpm, 380 V, 50 Hz electric motor. Mixing shafts are sealed by mechanical seal. The lid is equiped with inlets, light, inspection sight glass and is raised or lowred by electric motor.
The UV-99 spectrophotometer is an ideal solution for those looking for a fast and accurate spectrophotometer for the determination of nucleic acids and proteins, thanks to the use of a xenon lamp and diode array, it allows scans over the full measurement range, as well as measurements of dyes or other chemicals. Automatic measurement at 2 optical grog lengths Standard 1mm Short 0.2mm Sample volume: 0.5 - 2.5 ul Light source - xenon lamp Detector - CCD matrix of 3648 elements Wavelength range: 200- 850 nm Wavelength accuracy 1 nm Absorbance accuracy 0.002 A Measuring range 0.1 - 70 A Measuring range for DNA 2- 3500 ng/ul Measuring range for protein 0 -100mg/ml Repeatability of measurements 0,1 - 5 A ±0,1 5-75A ±2% Measurement time
Scanning in the visible light and ultraviolet range, equipped with a large graphic display. The devices large memory allows it to store up to 100 user measurement methods and up to 1000 results. Built-in USB port allows you to connect and save data to an external memory (Flash Drive). Technical parameters: - Reference beam optical system - Wavelength range: 190-1100 nm - Light source: xenon lamp - Detector: photodiode - Photometric range: -3.3 . +3.3 Abs - Spectral bandwidth: 4 nm - Wavelength accuracy ± 1nm - Wavelength resolution: 0.1 nm - Wavelength repeatability: ±0.5nm - Wavelength reproducibility: < 0.5nm - Photometric accuracy: o ± 0.003 Abs at 0.5 Abs o ± 0.005 Abs at 1.0 Abs o ± 0.010 Abs at 2.0 Abs - Drift: < 0.005 Abs/h - Scattered light: o < 1% at 198 nm (KCL) o < 0.1 %T at 220 nm (Nal) o < 0.05 %T at 340 nm (GG375) o < 0.05%T at 408 nm (GG435) - ...
Compact, dry-running, chemical-resistant pump systems with a range of vacuum control options that are ideal for many chemical and research laboratory applications. Both manual and automatic pump systems with built-in solvent library Close to 100% solvent recovery Optimum stability with multilingual digital display Maintenance-free drive system and proven long membrane life Quick and easy maintenance for user-friendly operation Inlet separator to protect the pump from liquid and particle ingress Outlet condenser for optimum solvent recovery Unregulated vacuum systems are used when the highest vacuum is required at all times. The manually adjustable vacuum regulator has a control valve with a precision regulator that is used to regulate the vacuum by acting as a bleed valve. The standard electronic two-point vacuum regulator uses a chemically resistant ...
Selling our Tubefiller in very good condition. Full LCD monitor easy control up to 6.000 units per hour ... más información
Conveying height 518 mm Inlet height approx. 500 mm Outlet height approx. 500-630 mm Tablet diam. 3-25 mm Deduster path total length 7 m Conveying capacity depending on tablet size 68,000-3,500,000 tablets/h Inlet adapter with nozzle diam. 50 mm Programme control C810 Metal check Ceia THS/PH21N with its own HMI Bad ejection into glass container Drive 100-240V/50/60Hz Spigot for dust extraction Mobile
Conveying height 1,290 mm Inlet height 620-780 mm Tablet diam. 3-25 mm Deduster path total length 15 m Conveying capacity depending on tablet size 68,000-3,500,000 tablets/h 2 inlet adapters: rectangular 115x80 mm and round with diam. 60 mm nozzle Programme control C920 with HMI Allen-Bradley Panel View Plus 600 Distributor V4000 with 6 outlets, automatic/manual change of outlets selectable via HMI Metal check Lock Met 30+ with its own HMI Bad ejection into glass container PLC Allen-Bradley MicroLogix Drive 100-240V/50/60Hz Nozzle for dust extraction Mobile
Conveying height 1,290 mm Inlet height 620-780 mm Tablet diam. 3-25 mm Deduster path total length 15 m Conveying capacity depending on tablet size 68,000-3,500,000 tablets/h 2 inlet adapters: rectangular 115x80 mm and round with diam. 60 mm nozzle Programme control C920 with HMI Allen-Bradley Panel View Plus 600 Distributor V4000 with 6 outlets, automatic/manual change of outlets selectable via HMI Metal check Lock Met 30+ with its own HMI Bad ejection into glass container PLC Allen-Bradley MicroLogix Drive 100-240V/50/60Hz Nozzle for dust extraction Mobile
Equipo de laboratorio Buchi Rotavapor R-220 Pro 230V + UNISTAT 430 Thermodynamic Thermostat ... más información